Rated Input Current
(D2D2502, 2504)
10.0 A (at 115 VAC) 5.5A (at 230 VAC)
BTU Rating
(D2D4112
D2D4106)
Maximum 1681 BTU/hr (at 100 VAC) 1646 BTU/hr (at 240 VAC)
BTU Rating
(D2D4106)
Maximum 1815 BTU/hr (at 100 VAC) 1776 BTU/hr (at 240 VAC)
BTU Rating
(D2D4312
D2D4324)
Maximum 2325 BTU/hr (at 100 VAC) 2270 BTU/hr (at 240 VAC)
BTU Rating
(D2D2502,
2504)
Maximum 940 BTU/hr (at 100 VAC) 907 BTU/hr (at 240 VAC)
Rated Steady-state
Power
(D2D4312,
D2D4324)
552 W (at 100 VAC),
536 W (at 240 VAC)
Rated Steady-state
Power
(D2D4112,
D2D4106)
360 W (at 100 VAC),
386 W (at 240 VAC)
Rated Steady-state
Power
(D2D2502, 2504)
215W (at 100 VAC),
211W (at 240 VAC)
Rated Steady-State
Power
(D2D4106)
410 W (at 100 VAC),
430 W (at 240 VAC)
Maximum Peak Power
(D2D4312, D2D4324)
682 W (at 100 VAC),
666 W (at 240 VAC)
Maximum Peak Power
(D2D4112, D2D4106)
500W (at 100 VAC),
515 W (at 240 VAC)
Maximum Peak Power
(D2D4004, D2D4009,
D2D4106)
540 W (at 100 VAC),
550 W (at 240 VAC)
Maximum Peak Power
(D2D2502 and D2D2504)
280W (at 100 VAC),
280 W (at 240 VAC)
Maximum Peak Power
385 W (at 100 VAC),
390 W (at 240 VAC)
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 82.4° F (28° C) maximum wet bulb
temperature, non-condensing
Non Operating
5 to 95% relative humidity (Rh), 101.7° F (38.7° C) maximum wet bulb
temperature, non-condensing
Temperature Range D2D
2502i, 2504i, D2D4112,
D2D4106, D2D4312
D2D4324
Operating
50° to 95°F (10° to 35°C) at sea level with an altitude derating of 1.8°F per
every 1000 ft (1.0°C per every 305 m) above sea level to a maximum of 10,000
ft (3050 m), no direct sustained sunlight. Maximum rate of change is 18°F/hr
(10°C/hr). The upper limit may be limited by the type and number of options
installed.
system performance may be reduced if operating with a fan fault or above
86°F (30°C)
Non Operating
(D2D2502i,
2504i, D2D4112, D2D4106,
D2D4312, D2D4324)
22° to 140° F (-30° to 60° C). Maximum rate of change is 36° F/hr (20° C/hr)
QuickSpecs
HP StoreOnce Backup systems
Technical Specifications
DA - 13218 Worldwide — Version 18 — September 28, 2012